8-15kV XLPE Insulated PVC Sheathed Unarmoured Power Cable 100/133% Insulation Levels
100% Insulation Levels (single conductor)
Conductor |
Insulation thickness ( mm ) |
Sheath thickness ( mm ) |
Overall Dia. approx. ( mm ) |
AC Test voltage ( kV / 5 min ) |
Cable weight approx. ( kg / km ) |
||
Size (AWG or MCM) |
Construction ( No. / mm ) |
Outside Dia. ( mm ) |
|||||
2 1 1/0 2/0 3/0 |
7/2.47 19/1.69 C.C. C.C. C.C. |
7.42 8.43 8.53 9.55 10.74 |
4.45 4.45 4.45 4.45 4.45 |
2.03 2.03 2.03 2.03 2.03 |
24.8 25.8 25.9 26.9 28.1 |
27 27 27 27 27 |
882 999 1101 1261 1461 |
4/0 250 300 350 400 |
C.C. C.C. C.C. C.C. C.C. |
12.07 13.21 14.48 15.65 16.74 |
4.45 4.45 4.45 4.45 4.45 |
2.03 2.03 2.03 2.03 2.03 |
29.5 30.6 31.9 33.0 34.1 |
27 27 27 27 27 |
1707 1925 2194 2460 2733 |
500 550 750 1000 |
C.C. C.C. C.C. C.C. |
18.69 20.65 23.06 26.92 |
4.45 4.45 4.45 4.45 |
2.03 2.03 2.03 2.79 |
36.1 38.0 40.5 46.1 |
27 27 27 27 |
3252 3807 4585 6068 |
100% Insulation Levels (Three conductor)
Conductor |
Insulation thickness ( mm ) |
Sheath thickness ( mm ) |
Overall Dia. approx. ( mm ) |
AC Test voltage ( kV / 5 min ) |
Cable weight approx. ( kg / km ) |
||
Size (AWG or MCM) |
Construction ( No. / mm ) |
Outside Dia. ( mm ) |
|||||
2 1 1/0 2/0 3/0 |
7/2.47 19/1.69 C.C. C.C. C.C. |
7.42 8.43 8.53 9.55 10.74 |
4.45 4.45 4.45 4.45 4.45 |
2.79 2.79 2.79 2.79 2.79 |
49.8 52.1 52.3 54.5 57.0 |
27 27 27 27 27 |
2895 3282 3589 4104 4750 |
4/0 250 300 350 400 |
C.C. C.C. C.C. C.C. C.C. |
12.07 13.21 14.48 15.65 16.74 |
4.45 4.45 4.45 4.45 4.45 |
2.79 2.79 2.79 2.79 2.79 |
59.9 62.4 65.1 67.6 71.7 |
27 27 27 27 27 |
5537 6225 7083 7930 9088 |
133% Insulation Levels (single conductor)
Conductor |
Insulation thickness ( mm ) |
Sheath thickness ( mm ) |
Overall Dia. approx. ( mm ) |
AC Test voltage ( kV / 5 min ) |
Cable weight approx. ( kg / km ) |
||
Size (AWG or MCM) |
Construction ( No. / mm ) |
Outside Dia. ( mm ) |
|||||
1 1/0 2/0 3/0 4/0 |
19/1.69 C.C. C.C. C.C. C.C. |
8.43 8.53 9.55 10.74 12.07 |
5.46 5.46 5.46 5.46 5.46 |
2.03 2.03 2.03 2.03 2.03 |
28.1 28.1 29.2 30.4 31.7 |
33 33 33 33 33 |
1103 1205 1369 1572 1822 |
250 300 350 400 500 |
C.C. C.C. C.C. C.C. C.C. |
13.21 14.48 15.65 16.74 18.69 |
5.46 5.46 5.46 5.46 5.46 |
2.03 2.03 2.03 2.03 2.03 |
32.8 34.1 35.3 36.4 38.3 |
33 33 33 33 33 |
2044 2317 2587 2863 3388 |
550 750 1000 |
C.C. C.C. C.C. |
20.65 23.06 26.92 |
5.46 5.46 5.46 |
2.03 2.79 2.79 |
40.3 44.5 48.3 |
33 33 33 |
3951 4919 6240 |
133% Insulation Levels (Three conductor)
Conductor |
Insulation thickness ( mm ) |
Sheath thickness ( mm ) |
Overall Dia. approx. ( mm ) |
AC Test voltage ( kV / 5 min ) |
Cable weight approx. ( kg / km ) |
||
Size (AWG or MCM) |
Construction ( No. / mm ) |
Outside Dia. ( mm ) |
|||||
1 1/0 2/0 3/0 4/0 |
19/1.69 C.C. C.C. C.C. C.C. |
8.43 8.53 9.55 10.74 12.07 |
5.46 5.46 5.46 5.46 5.46 |
2.79 2.79 2.79 2.79 2.79 |
56.9 57.1 59.3 61.8 64.7 |
33 33 33 33 33 |
3652 3974 4498 5156 5956 |
250 300 350 400 |
C.C. C.C. C.C. C.C. |
13.21 14.48 15.65 16.74 |
5.46 5.46 5.46 5.46 |
2.79 2.79 2.79 2.79 |
67.1 69.9 74.1 76.4 |
33 33 33 33 |
6669 7536 8699 9601 |
website: www.caledonian-cables.com